EtherCAT Servo Motion Control System AC Servo Controller For Cardboard Cap Feeder
Product Details:
Place of Origin: | China |
Brand Name: | Vector |
Certification: | CE |
Model Number: | VEC-VC-01233HC-M-E/180MB-4R520A33F-MF2 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 kit |
---|---|
Price: | USD 300-450 / kit |
Packaging Details: | 280*208*78mm |
Delivery Time: | 3-5 work days |
Payment Terms: | T/T, Western Union, L/C |
Supply Ability: | 500 kits/month |
Detail Information |
|||
Voltage: | 380V | Power: | 4.5KW |
---|---|---|---|
Rated Current: | 12A | Rated Speed: | 2000 Rpm |
Rated Torgue: | 21.5N.m | Phase: | 3 Phase |
Motor Flange Size: | 180mm | Communication Protocols: | Modbus/CANopen/EtherCAT |
Model: | VEC-VC-01233HC-M-E/180MB-4R520A33F-MF2 | Application: | Cardboard Cap Feeder |
High Light: | 2000rpm Servo Motion Control System,EtherCAT Servo Motion Control System,EtherCAT AC Servo Controller |
Product Description
EtherCAT/Canopen Bus Type Servo Amplifier Controller For Cardboard Cap Feeder
EtherCAT/Canopen Bus Type Servo Amplifier
AC Power 380V 4.5KW
Three phase with 17/23bit Tamagawa absolute encoder;
Modbus/CANopen/EtherCAT Commucation Protocol Type
Products Description
Products | AC Servo Drive Controller For Cardboard Cap Feeder |
Brand | Vector |
Model No. | VVEC-VC-01233HC-M-E/180MB-4R520A33F-MF2 |
Power | 4.5KW |
Voltage | 380V |
Phase | Three Phase |
Rated Speed | 2000 rpm |
Rated Current | 9.5A |
Rated Torgue | 21.5N.m |
Communication Protocols | Modbus/CANopen/EtherCAT |
Key Name | Key function |
Mode | mode switch, return to the previous menu |
▲(add) | increase flashing bit value of the LED digital tube |
▼(dec) | Decrease flashing digit value of the LED digital tube |
◄◄(shift) | Moves the blinking LED tube to the left; checks the high value of data longer than 5 bits; Fault reset;execute Fn function |
SET | read/write parameter values |
Installation:
● Install the driver on a dry and sturdy platform. Maintain good ventilation and
heat dissipation during installation and maintain good grounding.
● Please install in the specified direction to avoid malfunction.
● When installing, please ensure that the servo driver is kept at a specified
distance from the inner surface of the cabinet and other machines, otherwise it may cause fire or malfunction.
Installation Environment Requirements |
Atmospheric Pressure | 86~106kPa |
Mbient Humidity | 0~55℃ | |
Ambient Temperature | 0~90%RH | |
IP Rating | IP20 | |
Vibration | 0~4.9m/s^2 |
● When installing, do not block the suction and exhaust ports, and do not allow foreign objects inside the product
to enter, otherwise it may cause malfunction or fire due to aging of internal components.
● Do not place heavy objects on or under this product as this may result in injury.
● Please install in the following environment:
1.places without direct sunlight;
2.Locations where the ambient temperature is in the range of 0 ° C to 55 ° C;
3.Relative humidity in the range of 0% to 95%, and no condensation;
4.Locations free of water droplets, vapors, dust and oily dust;
5.Locations where there is no high heat device;
6.Non-corrosive, flammable gas and liquid sites;
7.It is not easy to splash water, oil and medicine;
8.places that are not exposed to radioactive radiation;
9.Strong and vibration-free places;
10.Locations where there is no electromagnetic noise interference.
Wiring precautions
● It is recommended not to use single-phase 220V for main power supply,
which may cause damage to electrolytic capacitor due to lack of phase.
● Do not change the wiring during power-on, otherwise it may cause electric shock or injury.
● Please perform wiring or inspection by professional technicians, otherwise it
may cause electric shock or product failure.
● Please carefully confirm the wiring and power supply. The output circuit
may be short-circuited due to wiring errors or application of different voltages. The brake does not operate
when the above fault occurs, which may result in mechanical damage or personal injury.
● Do not connect the input power cable to the U, V, and W terminals of the
drive. Otherwise, the servo driver will be damaged.
● When wiring, do not pass the power cable and signal cable through the same pipe, and do not bundle them
together. The distance between the two should be more than 30cm to avoid interference.
● The driver ground terminal must be grounded to avoid leakage and reduce the interference of the system,
and the diameter of the ground wire should be the same as or above the power supply line.
● When connecting the AC power supply and DC power supply to the servo unit, connect to the specified terminal.
Failure to do so may result in malfunction or fire.
● For the wiring length, the command input line is up to 3m and the encoder line is up to 20m.
● Use a twisted-pair shielded cable for the signal cable and encoder cable, and ground the shield with a single end.
●The U, V, W terminals of the driver and the U, V, and W terminals of themotor should be connected one by one
according to the name. If it is wrong connected, the motor cannot operate normally.
● Common DC bus products require pressure sensitive resistors and the wiring is secure.
● Please check the power after the power is off for at least 5 minutes. Even if
the power is turned off, high voltage may remain inside the servo drive. Therefore, do not touch the power terminal
within 5 minutes after the power is turned off, otherwise it may cause electric shock.
● Do not turn the power ON/OFF frequently. When it is necessary to continuously turn ON/OFF the power, please
control it once or less in 1 minute. Since the power supply section of the servo driver has a capacitor, a large charging
current (charge time of 0.2 seconds) flows during the ON/OFF power supply. Therefore, if the power is turned ON/OFF
frequently, the performance of the main circuit components inside the servo driver will be degraded.
● Do not apply power when the terminal block screws are loose or the cable is loose. Otherwise, it may cause fire.
● Take appropriate shielding measures in the following locations, otherwise the machine may be damaged:
1. Locations that cause interference due to static electricity;
2. A place that produces a strong electric field or a strong magnetic field;
3. Locations where there may be radiation radiation;
4. A place with a power cord nearby.
Accessories:
Accessory name | Image | ||
Satandard Spare Parts | Power terminal | Adapt to E1,E2 structure drive | |
Cn3 encoder plug | Encoder plug on the driver side | ||
Cn4 control terminal plug | Input/output signal terminals,user wiring | ||
Encoder connection line | The standard cable length is 3, 5, 8, 10, 13, 15 meters, according to customer needs Provide independent connector |
||
Power line | The standard cable length is 3, 5, 8, 10, 13, 15 meters, according to customer needs Provide independent connector |
||
Drive monitoring line | Connect and adjust the software for remote monitoring and firmware update | ||
Purchasing Spare Parts | USB to RS232 Adapter cable | If necessary, self purchase | |
Ethernet communication line | If necessary, self purchase |
Packing:
Packing details of Servo Drive | |||||
Products | E1(3-6A) | E2(7-12A) | E3(16-27A) | C015(32-38A) | C022(45-60A) |
Ctn. Size | 280*208*78 | 280*208*112 | 375*290*155 | 440*296*288 | 510*305*325 |
Packing details of Motion Controller | |||||
Products | VA Motion | VA Expansion | VE Motion | VE Expansion(32) | VE Expansion(76) |
Ctn. Size | 176*165*78 | 127*75*70 | 144*128*69 | 176*164*78 | 316*164*78 |
Delivery Time and Shipping Way
Quantity | 1-5 kits | 50-100 kits | 200-500 kits |
Delivery time | Within 3 days | 5-10 days | 15-25 days |
1. For small order we always can delivery out within 1 week.
2. Our products can be shippied via Air, Land or Sea.
Cetificates:
1. CE (EU Safety Standard);
2. IEC/EN61800-5-1:2007 (Safety requirements for electrical, thermal and energy in Section 5-1 of the
variable speed electric driver system), corresponding to the national standard GB12668.501-2013;
3, IEC / EN61800-3: 2004 + A1 (speed control electric driver system part 3 electromagnetic compatibility
standards and its specific test methods), corresponding to the national standard GB12668.3-2012.